Version 2.0fc 1
MODEL CF-04 CROSSFIRE STOVE
FIREPLACE INSERT, (FLEX FUEL VERSION)
USA & CANADA TEST: TESTED BY:
ASTM E 1509-04, UL 1482, WARNOCK HERSEY
ULC S627, ULC/ORD C1482 (and ULC S628
If listed for fire
p
lace insert installation in Canada
)
© 2011 COUNTRY FLAME
COUNTRY FLAME TECHNOLOGIES
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
WARNING: If the directions in this manual are not followed exactly, a fire
may result causing property damage, personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammables (vapor or liquids) in or
around the vicinity of this appliance.
Installation and repair must be performed by a qualified service agency.
Always check with local jurisdiction or code agency before installing this
product. Local jurisdiction may be requiring a permit prior to installation.
MOBILE HOME APPROVED
Przeglądanie stron 0
1 2 3 4 5 6 ... 53 54

Podsumowanie treści

Strona 1 - COUNTRY FLAME TECHNOLOGIES

Version 2.0fc 1 MODEL CF-04 CROSSFIRE STOVE FIREPLACE INSERT, (FLEX FUEL VERSION) USA & CANADA TES

Strona 2 - SAFETY NOTES

Version 4.0 10 PARTICULAR PURPOSE, ARE DISCLAIMED. IT IS UNDERSTOOD AND AGREED THAT AES’S LIABILITY UNDER THIS WARRANTY SHALL BE LIMITED

Strona 3

Version 4.0 11 American Energy Systems, Inc 150 Michigan Street SE Hutchinson, MN 55350 Fold Here Name Address

Strona 4

Version 4.0 12 THE CROSSFIRE OPERATION FEATURES Country Flame designed and built the CF04 stove to burn 100% shelled corn. Unlike conve

Strona 5 - 5

Version 4.0 13 FIGURE 2: CROSSFIRE COMPONENTS SAFETY FEATURES The Crossfire comes standard with a number of advanced safety features; h

Strona 6 - TABLE OF CONTENTS

Version 4.0 14 stable operation of the Crossfire. Fortunately, there are simple, reliable, and cost effective power backup solutions ava

Strona 7 - Version 4.0 7

Version 4.0 15 OPERATING REFERENCE GUIDE CROSSFIRE – FLEX STOVE (SEE FIGURE #3) • DO NOT use any other ignition accelerant other than i

Strona 8 - FORWARD

Version 4.0 16 The stir rod will be controlled by the control board. This stir rod assists in mixing fuel with air in the burn pot. Th

Strona 9 - WARRANTY

Version 4.0 17 FIGURE 4A: CONTROL BOARD BLOCK DIAGRAM Input Voltage Alternating Current (AC) Input provided by the local pow

Strona 10 - Version 4.0 10

Version 4.0 18 FIGURE 5 displays the Country Flame Control Board front panel. Each function of the Control Board is identified.

Strona 11 - Hutchinson, MN 55350

Version 4.0 19 OPERATING INSTRUCTIONS (Using self igniter systems, if auto ignition system (optional) has been installed) NOTE: Each t

Strona 12 - THE CROSSFIRE OPERATION

Version 4.0 2SAFETY NOTES The Crossfire Model CF-04 fuel stove is significantly different from a conventional wood-burning stove. One major differ

Strona 13 - Version 4.0 13

Version 4.0 20 The auger feed rate on each setting is pre-programmed but may be changed if necessary. The “Auger Trim” button will overr

Strona 14 - Version 4.0 14

Version 4.0 21 OPERATING INSTRUCTIONS (Without using system igniter) NOTE: Each time the stove is started, the firepot should be checke

Strona 15 - OPERATING REFERENCE GUIDE

Version 4.0 22 and hold the ‘Auger Trim’ button along with the heat level button arrow up or heat level button arrow down, depending on d

Strona 16 - Version 4.0 16

Version 4.0 23 to starting. You can hold the auger button down to override the system and manually prime the auger. The room fan button

Strona 17

Version 4.0 24 AC MODEL WIRING DIAGRAM WARNING: DISCONNECT POWER BEFORE SERVICING THIS UNIT.

Strona 18 - Version 4.0 18

Version 4.0 25 STOVE SPECIFICATIONS TABLE 2 shows the physical dimensions of the Crossfire product. CROSSFIRE DIMENSIONS (IN INCHES) STO

Strona 19 - OPERATING INSTRUCTIONS

Version 4.0 26 move to that heat setting anytime the thermostat calls for heat. Otherwise, when the thermostat no longer calls for heat,

Strona 20 - Version 4.0 20

Version 4.0 27 INSTALLATION INSTALLATION PREPARATION Country Flame strongly recommends the Crossfire be installed by a certified profess

Strona 21

Version 4.0 28 installation into an approved masonry or zero clearance fireplaces, the use of single or double-wall flue pipe will not af

Strona 22 - Operation

Version 4.0 29 CHIMNEY It is extremely important that a Crossfire stove be vented into a non defective, clean, and properly lined chimne

Strona 23 - Version 4.0 23

Version 4.0 3 WARNING: Maintain all minimum safety clearances of the Crossfire stove and chimney system. Never install the Crossf

Strona 24 -

Version 4.0 30 combustion. In all cases, the flue must be relined with a listed liner system, such as HomeSaver Chimney Liner. If you

Strona 25 - DIMENSIONS (IN INCHES)

Version 4.0 31 carpet to come in contact with any part of the Crossfire insert. Maintain clearances to combustibles as specified in TABL

Strona 26 - Version 4.0 26

Version 4.0 32 MOBILE HOME INSTALLATION WARNING: DO NOT INSTALL A COUNTRY FLAME CROSSFIRE STOVE IN ANY MOBILE HOME SLEEPING ROOM. WARN

Strona 27 - INSTALLATION

Version 4.0 33 Do not violate minimum clearances with approved thermal barriers. Manville’s CERAFORM 126 is an example of an approved in

Strona 28 - FIGURE 11: CROSSFIRE SHROUD

Version 4.0 34 3. At no time should a floor protector be placed on top of carpeting. Carpeting must be removed and the floor protection

Strona 29 - Version 4.0 29

Version 4.0 35 certified professional to install a flue gas pellet venting system. Do not deviate from the pellet flue manufacturer’s in

Strona 30 - Version 4.0 30

Version 4.0 36 FIGURE 15: MOBILE HOME CHIMNEY INSTALLATION

Strona 31 - Version 4.0 31

Version 4.0 37 MAINTENANCE REQUIREMENTS GENERAL REQUIREMENTS The Crossfire Model CF-04 has minimal maintenance requirements; however, fa

Strona 32 - MOBILE HOME INSTALLATION

Version 4.0 38 STOVE DOOR ADJUSTMENT The Crossfire door may require fine adjustment due to variations in the door, the gasket material, d

Strona 33 - Version 4.0 33

Version 4.0 39 the door glass. Removal of these glass retaining clips can be accomplished with household tools. Order the necessary rep

Strona 34 - Version 4.0 34

Version 4.0 4 CAUTION: Operate the Crossfire with the fuel hopper lid closed at all times. Failure to keep the hopper lid closed

Strona 35

Version 4.0 40 In order to thoroughly clean the exhaust chamber, the Crossfire has two cleaning ports that provide access to the exhaust

Strona 36 - 36

Version 4.0 41 a period of use can lead to one or both exhaust chambers becoming blocked and thus causing the stove to burn inefficientl

Strona 37 - MAINTENANCE REQUIREMENTS

Version 4.0 42 APPENDIX A: TROUBLESHOOTING GUIDE Shut off the power to the unit and allow it to cool off when performing cleaning and m

Strona 38 - Version 4.0 38

Version 4.0 43 APPENDIX A: TROUBLESHOOTING GUIDE (CONT’D) Stirring Paddles do not turn The chain drive for the stirring paddles needs t

Strona 39 - Version 4.0 39

Version 4.0 44 APPENDIX B: MAINTENANCE GUIDE Shut off the power to the unit and allow it to cool off when performing cleaning and mainte

Strona 40 - Version 4.0 40

Version 4.0 45 APPENDIX B: MAINTENANCE GUIDE (CONT’D) Cleaning the Glass To clean glass, use a mild non-abrasive cleaner when the sto

Strona 41 - Version 4.0 41

Version 4.0 46 APPENDIX B: MAINTENANCE GUIDE (CONT’D) Replacing the Door / Glass Gaskets To replace the gaskets, remove the door by

Strona 42 - PROBLEM SOLUTION

Version 4.0 47 APPENDIX C: TECHNICAL SPECIFICATIONS Fuel Type: #2 Yellow Shelled Corn Fuel (CLEANED) Hardwood Pellet Fuel Moi

Strona 43 - (CONT’D)

Version 4.0 48 APPENDIX E: COMBUSTION BASICS An understanding of Combustion Basics will assist in resolving problems with a variety o

Strona 44 - Version 4.0 44

Version 4.0 49 Combustion Temperature: The temperature required to ensure the release of flammable vapors. To sustain combustion, the he

Strona 45 - Maintenance

Version 4.0 5 CERTIFICATION SAFETY LABEL (sample)

Strona 46 - 46

Version 4.0 50 The obvious advantage of Corn or wood pellets over conventional chopped wood logs is the consistency of the fuel both from

Strona 47 - Intelli-Choice Control Board

Version 4.0 51 As a final note, the two basic stages of corn burning are: a) Somewhere around 1100o F the corn fuel particles have comb

Strona 48 - Version 4.0 48

Version 4.0 52 APPENDIX F: REPLACEMENT PARTS REPLACEMENT PARTS Part Number Description Number per CROSSFIRE CF04-P72 BURN

Strona 49 - CORN COMBUSTION BASICS

Version 4.0 53 APPENDIX F: REPLACEMENT PARTS (cont’d) REPLACEMENT PARTS Part Number Description Number per CROSSFIRE INSERT CF0

Strona 50 - Version 4.0 50

Version 4.0 54 APPENDIX G: LABELS REPLACEMENT LABELS Part Number Description Number per CROSSFIRE INSERT PP-483 CAUTION LABEL

Strona 51 - Version 4.0 51

Version 4.0 6 TABLE OF CONTENTS SAFETY NOTES...

Strona 52 - Version 4.0 52

Version 4.0 7 MOBILE HOME RULES ...

Strona 53 - Version 4.0 53

Version 4.0 8 FORWARD COUNTRY FLAME Country Flame has worked for over two decades in researching and developing biomass fuel burning st

Strona 54 - APPENDIX G: LABELS

Version 4.0 9 AMERICAN ENERGY SYSTEMS INC. LIMITED PRODUCT WARRANTY This warranty is in effect on all products sold after 01/01/2009 and